Why Is My Scale Not Working? A Simple Troubleshooting Guide
- Cody
- Aug 7
- 3 min read
If your industrial scale has stopped working, don't immediately assume the load cell has failed.
Many weighing problems are caused by a loss of excitation voltage, damaged wiring, failed load cells, or a faulty indicator.
The troubleshooting steps below follow the same process our technicians use to isolate the problem before replacing expensive components.

Step 1: Is the Indicator Turned On?
Before testing anything else, verify the indicator has power.
Check:
Display is illuminated
Power cord is connected
Circuit breaker hasn't tripped
Power supply is functioning
No blown fuses
If the indicator won't power on, resolve the power issue before moving on.
Step 2: Check for Excitation Voltage
Once the indicator is powered on, measure the excitation voltage.
Measure between:
+EXC
-EXC
Most indicators provide between 5 and 15 VDC.
If Excitation Voltage Is Present
The indicator is supplying power to the load cells.
Proceed to Step 3.
If There Is No Excitation Voltage
Disconnect the load cell(s) from the indicator and measure the excitation voltage again.
Excitation Returns
If the excitation voltage returns after disconnecting the load cells, the load cell circuit is pulling the excitation voltage down.
This usually indicates one or more failed load cells or a shorted load cell cable.
Still No Excitation Voltage
If there is still no excitation voltage with all load cells disconnected, the indicator has likely failed and should be repaired or replaced.
Step 3: Is Your Scale Using One Load Cell or Multiple Load Cells?
This changes the troubleshooting process.
Single Load Cell
Inspect the cable for:
Cuts
Pinched insulation
Moisture
Rodent damage
Broken strain relief
If the cable appears normal, proceed to load cell testing.
Multiple Load Cells
If your system uses multiple load cells, each load cell should be tested individually.
Disconnect each load cell from the junction box one at a time.
This helps isolate which load cell is causing the problem.
Step 4: Check the Millivolt Output
Using a digital multimeter:
Measure between:
+SIG
-SIG
A properly functioning installed load cell will typically read between 0 and 5 mV, depending on the system's dead load.
Warning Signs
Greater than 10 mV
Negative millivolt reading
Unstable output
Output that does not change when weight is applied
These conditions often indicate a failed or damaged load cell.
Step 5: Isolate the Problem Load Cell
If multiple load cells are connected:
Disconnect one load cell.
Does the indicator begin operating normally?
Yes
The disconnected load cell is likely defective.
Reconnect the remaining load cells and continue testing to verify there are no additional failures.
No
Reconnect that load cell and disconnect the next one.
Repeat the process until the faulty load cell(s) have been identified.
Remember that more than one load cell can fail, especially after events such as lightning strikes, flooding, or severe overloads.
Step 6: Confirm the Diagnosis
Once the suspect load cell has been identified:
Compare resistance readings to the manufacturer's datasheet.
Inspect the cable and connector.
Verify the load cell is not mechanically damaged.
Confirm there is no binding or obstruction affecting the scale.
Replacing components before completing these checks can lead to unnecessary repairs.
Need Help Troubleshooting Your Scale?
If you've completed these tests and are still unsure what's causing the problem, our technicians can help.
Whether you're troubleshooting a truck scale, floor scale, tank scale, livestock scale, or other industrial weighing system, we can help determine whether the problem is the indicator, load cell, junction box, wiring, or another component.